Iron II Test

Iron Test II Console
Iron Test II Console

Patent No. 2910933

Iron is the main indicator of wear in 2 stroke diesel engines. Testing cylinder drain oil for iron content and residual base number (BN) is a common technique for screening drain oil samples on board seagoing vessels.

CM Technologies introduces a novel technology for testing iron on site. The new and improved Iron Test is faster, easier, and more accurate than any other available method.

The CMT Iron Test II is a novel and patented method based on a simple two-component wet chemistry that is measured in an electronic photometer.

An electric shaker assists the user in performing the test.
The test procedure takes only 3 minutes to obtain an accurate iron test result. For higher iron readings, the user can perform a second test to measure only the corrosive iron. This will provide the values for total, corrosive, and abrasive iron.
Iron glass Vial after filtration
Iron glass Vial after filtration

The iron content in the cylinder drain oil is an indicator of the wear and corrosion in the cylinder liner. By monitoring the iron content and taking remedial actions promptly, the cold corrosion and abrasive wear in the cylinder liner can be avoided.

The CMT CDO BN Test Kit and the Electronic Iron Analysis Kit allow monitoring of the most critical parameters of the drain oil on-site, providing the user with the necessary information to optimize the cylinder oil’s feed rate and prevent unnecessary wear of the individual cylinder liners. Both kits are also available as a combined CDO Test Kit.

Your Benefits

  • Greatly increased repeatability and accuracy (+/- 20 ppm)
  • Differentiation between corrosive and abrasive iron
  • No soot dependence on the test allows for the most reliable results
  • Fastest onsite wet chemistry test
  • Intuitive usage due to touchscreen functionality
  • Large memory for storing data
  • Easy trending thanks to a high-resolution graphic display
  • Simple USB data transfer to a PC
  • No hazardous chemicals involved

ordering
Information

OTK-CT-11228
Electronic Iron II SM Test Kit
Range: 50 – 1500 ppm
Corrosive iron: 0 – 100 % of total
Abrasive iron: 0 – 100 % of total
Accuracy: +/- 20 ppm
Repeatability: 10 ppm
Test Time (ave.): 3 min. per Test
No. of initial Tests: 50
Memory: last 20 reading / cyl.
14 cylinders
Reagents: non-hazardous

SW-C00002-CT
Download Option Console
License for data download

OTS-CT-13034
Iron II Test Reagent Pack (Version II)
No. of Tests: 50 drain oil samples
Reagents: non hazardous

OTS-CT-13024
Iron Test Reagent Pack (Version I)
No. of Tests: 50
Reagents: non hazardous

OTS-CT-13029
Glass Vial Consum. Pack (for S/N > 400)
Glass Vials with cap: 100

OTR-CT-12010
Vial Cleaner
Size 250 ml
Reagent: non hazardous

OTS-CT-13025
Iron Test Consumables Pack (Version I)
Glass Tubes (blue caps): 24
Set of Syringes